IPC / rs232/485/422
本公司提供英文報價單, 以及包裝出貨服務. We will send the quotation to you and package servise if any requirement. 無
Line ID:
to take care your requirement about the IPC products.
ID:
以便專案處理您的需求
Trycom technology Co.Ltd.
Po Chun Shen
# # # # # # # # # # # # # # # # # # # # # #
A USB to RS-232/RS-422/RS-485 isolated converter is used to connect devices with serial communication interfaces (RS-232, RS-422, RS-485) to a USB port on a computer. Here are some common applications:Industrial Automation: Connecting PLCs, motor controllers, and sensors to computers for monitoring and control.Instrumentation: Interfacing scientific instruments, data loggers, and measurement devices with computers.Serial Device Management: Managing serial devices like modems, printers, and barcode scanners via USB.Embedded Systems Development: Communicating with microcontrollers and embedded systems for programming and debugging.Legacy Equipment Integration: Connecting older equipment that uses serial communication to modern computers.POS Systems: Integrating point-of-sale terminals and peripherals with computers.Networking: Configuring and managing network equipment that uses serial interfaces.Home Automation: Connecting home automation devices and systems to computers for control and monitoring.The isolation feature protects both the computer and the serial devices from electrical interference and surges, ensuring reliable and safe data transmission.
Line ID:
to take care your requirement about the IPC products.
ID:
以便專案處理您的需求
Trycom technology Co.Ltd.
Po Chun Shen
# # # # # # # # # # # # # # # # # # # # # #
RS-485 is a standard for serial communication that is widely used in industrial and commercial applications. It supports long-distance and high-speed data transmission, which makes it ideal for various environments. Here's an overview of some common applications where RS-485 is utilized:Industrial Automation:PLC Communication: Programmable Logic Controllers (PLCs) often use RS-485 for communication between devices on the factory floor.SCADA Systems: Supervisory Control and Data Acquisition (SCADA) systems use RS-485 to connect remote devices to central control systems.Building Automation:HVAC Systems: Heating, Ventilation, and Air Conditioning systems use RS-485 for communication between controllers and sensors.Lighting Control: Many lighting systems use RS-485 to manage and control lighting networks within buildings.Energy Management:Smart Meters: RS-485 is used in smart meter applications for transmitting data over long distances.Solar Inverters: Communication between solar inverters and monitoring systems often employs RS-485.Security Systems:Access Control: RS-485 is used in access control systems to connect card readers, keypads, and control panels.Surveillance: It supports communication between cameras and control systems in CCTV networks.Transportation:Traffic Signals: RS-485 is used to synchronize and control traffic lights.Railway Systems: Communication within railway control systems and between different components.Medical Equipment:Patient Monitoring Systems: RS-485 is used to connect various monitoring devices in medical environments.Environmental Monitoring:Weather Stations: RS-485 enables communication between sensors and central data collection units in weather monitoring systems.Home Automation:Smart Home Devices: Many smart home systems use RS-485 for reliable and long-distance communication between devices.In these applications, RS-485's robustness, noise immunity, and ability to support multiple devices on the same bus make it a popular choice.
Line ID:
to take care your requirement about the IPC products.
ID:
以便專案處理您的需求
Trycom technology Co.Ltd.
Po Chun Shen
# # # # # # # # # # # # # # # # # # # # # #
Ethernet I/O applications involve using Ethernet communication to manage input/output (I/O) devices in an industrial or automation environment. These applications are essential for modern industrial automation, allowing for the integration and communication between various sensors, actuators, and control systems over a standard Ethernet network. Here are some key points about Ethernet I/O applications:Real-Time Communication: Ethernet I/O systems enable real-time data exchange between devices, which is critical for applications requiring immediate responses, such as industrial automation and process control.Scalability: These systems are scalable, allowing for the easy addition of new devices without significant changes to the existing infrastructure.Standardization: Ethernet is a widely accepted standard, ensuring compatibility and interoperability between different devices and manufacturers.Remote Monitoring and Control: Ethernet I/O allows for remote monitoring and control of devices, enhancing the ability to manage systems from different locations.Reduced Wiring: By using Ethernet for communication, the need for extensive wiring is reduced, simplifying installation and maintenance.Integration with IT Systems: Ethernet I/O systems can easily integrate with existing IT infrastructure, enabling better data analysis, storage, and access.Examples of Use: Common applications include factory automation, building management systems, process control in manufacturing, and smart grid technologies.If you have a specific question or need more detailed information about a particular aspect of Ethernet I/O applications, feel free to ask!
Line ID:
to take care your requirement about the IPC products.
ID:
以便專案處理您的需求
Trycom technology Co.Ltd.
Po Chun Shen
# # # # # # # # # # # # # # # # # # # # # #
Bluetooth RS-232, RS-422, and RS-485 converters are used to wirelessly connect devices that traditionally communicate over these serial protocols. Here are some applications of these converters:Industrial Automation: In factories and plants, these converters are used to connect sensors, controllers, and other devices to a central monitoring system wirelessly. This helps in reducing the clutter of wires and makes it easier to reconfigure the layout.Remote Data Collection: These converters enable remote devices to send data back to a central system without the need for physical cabling. This is useful in environments where running cables is impractical or impossible.Building Management Systems (BMS): In large buildings, these converters can be used to connect various control systems (like HVAC, lighting, security) to a central management system wirelessly.Retail and Point-of-Sale (POS) Systems: Wireless RS-232 converters can connect POS terminals and other retail equipment to central servers, improving flexibility in store layouts.Healthcare: Medical devices often use serial communication. Bluetooth converters can wirelessly connect these devices to monitoring systems, allowing for better patient mobility and reducing cable clutter in medical facilities.Automotive Diagnostics: Mechanics can use these converters to connect diagnostic tools to vehicles wirelessly, making it easier to move around the vehicle without being tethered by cables.Telecommunications: In telecom networks, these converters can be used to connect equipment to management systems wirelessly, reducing the need for extensive cabling.Energy Management: For monitoring and controlling energy systems like solar panels, wind turbines, and power meters, these converters can facilitate wireless communication with central monitoring stations.By using Bluetooth technology, these converters offer the advantage of easy installation, flexibility in device placement, and reduction in cable maintenance.
Line ID:
to take care your requirement about the IPC products.
ID:
以便專案處理您的需求
Trycom technology Co.Ltd.
Po Chun Shen
# # # # # # # # # # # # # # # # # # # # # #
Fibre to RS-232, RS-485, RS-422 converters are used to convert signals between fibre optic communication systems and serial communication standards. Here's how they are typically applied:Long-Distance Communication: Fibre optics can transmit data over much longer distances compared to copper-based RS-232, RS-485, and RS-422 connections. Converters are used to extend the range of these serial communications.Electromagnetic Interference (EMI) Protection: Fibre optics are immune to electromagnetic interference, making these converters ideal for use in environments with high EMI, such as industrial settings or near heavy machinery.Isolation: Fibre optics provide electrical isolation between devices, reducing the risk of ground loops and improving safety in electrical systems.Security: Fibre optics are harder to tap into than copper cables, providing more secure data transmission for sensitive applications.Data Rate Improvement: Fibre optics can support higher data rates, making them suitable for applications that require high-speed data transfer.Industrial Automation: In factory automation systems, converters enable communication between PLCs (Programmable Logic Controllers), sensors, and actuators over long distances.Telecommunications: Converters are used in telecom infrastructure to connect various equipment and extend the reach of the network.SCADA Systems: In Supervisory Control and Data Acquisition (SCADA) systems, these converters facilitate reliable communication between central control systems and remote terminal units (RTUs).Building Management Systems: They are used to link building management systems for HVAC, security, and lighting control over large buildings or campuses.Transportation: Converters are used in transportation systems for communication between control centers and various devices, such as traffic signals, toll systems, and railway signaling.In summary, fibre to RS-232, RS-485, RS-422 converters are critical in any application where long-distance, high-speed, secure, and reliable serial communication is required.
預加賴聯絡請加以下
Line ID:
to take care your requirement about the IPC products.
ID:
以便專案處理您的需求
Trycom technology Co.Ltd.
Po Chun Shen
USB to RS-232, RS-422, RS-485 adapters are used to connect devices with these serial communication interfaces to a computer or other device with a USB port. Here’s a brief overview of each type and its common uses:USB to RS-232:Use: RS-232 is a standard for serial communication transmission of data. It's commonly used for connecting older peripherals like modems, printers, and industrial equipment to computers.Applications: Industrial automation systems, laboratory equipment, networking hardware configuration, and legacy hardware interfaces.USB to RS-422:Use: RS-422 allows for differential signaling, which makes it more resistant to noise over longer distances compared to RS-232. It’s often used in industrial environments.Applications: Factory automation, process control, and environments where communication over long distances or in noisy conditions is necessary.USB to RS-485:Use: RS-485 also uses differential signaling and supports multiple devices on the same bus (multi-drop). It's used for long-distance and high-speed communication.Applications: Building automation, industrial control systems, and any system requiring communication between multiple devices over long distances.These adapters provide a way to modernize systems and ensure compatibility between legacy hardware and modern computers, which typically lack native serial ports.
預加賴聯絡請加以下
Line ID:
to take care your requirement about the IPC products.
ID:
以便專案處理您的需求
Trycom technology Co.Ltd.
Po Chun Shen
預加賴聯絡請加以下ID:
黑咖啡工業設備
好友加入中
黑咖啡工業設備
大家好
We have whole series IPC products in our product operation line in Taipei ,Taiwan.
If clients have any requirement, please contact us with the following information:
Salesmanager: Johnson Shen
Cell phone :886 0937956696
Email:[email protected]
TRP-C24H 16 channel isolated digital output MODBUS TCP module
1. Introduction
The TRP-C24H is an Isolated open collector digital outputs Modbus TCP Module, It provides 16 channels output
open collector signal (100mA) to driven your devices on network, It supports 3 communication Protocols, TRP-ASCII,
Modbus RTU / ASCII, It can be easy and convenient to use application supports Modbus.
Software engineers can use the TRP-ASCII or Modbus RTU/ASCII command set quickly and easily integrated into
the self-development program, such as Microsoft VB, VC...
The TRP-C24H built-in independent IP, WEB-browsing more convenient to rewrite the configuration and collect
information through computers, tablet computers, smart phones, will be available!
The TRP-C24H built-in watchdog Hardware ensure the normal operation of the module, and a built-in voltage
monitoring to ensure that the boot, excellent and advanced hardware for harsh environment.
The TRP-C24H can TRP-C26H, 16 remote control directly, do not need to run the software and equipment.
When TRP-C24H and TRP-C26H are paired, they can support 16 channels remote control does not require any
drivers and software support.
The TRP-C24H is also offers the maximum connection 16 host client to link the network server that is easy to
operate in Modscan32 ,Modbus Poll,CAS Modbus Scanner and SCADA ...application uses TCP mode and
Virtual-COM mode.
1-1Features
Wide input range DC power supply.
Automatically determine 3 TRP-ASCII and Modbus RTU/ASCII communication protocol.
16 TCP Port can be open at the same time.
Heart Beat function ensures a reliable communicating connection.
Support Virtual-COM mode.
IO status can be set in the boot.
WEB PAGE can be directly output and read IO status.
Easily update the firmware using the Internet.
Back to factory configuration by external touch Button.
Auto reconnection when power or Ethernet fail.
Digital output signal with 3750Vrms isolation protection.
Built-In watchdog function prevents system boot fail.
LED for each I/O channels working status.
Support Auto-MDIX twisted pair crossover detection and Auto-Correction.
Power/Link/16 CH DO LED indicator.
DIN-Rail and panel mount support.
Dual power input select from screw terminal or DC-Jack.
TRP-C24 Function-16 channels digital output RS485 MODULE
1.Introduction
The TRP-C24, an isolated output open collector RS-485 module, provides 16 digital outputs
channels that allow you output open collector signal (100mA) to driven your devices on RS-485
network. All channels feature screw terminals for convenient connection of field signals as well
as LED’s to indicate channel working status. All outputs are equipped with photo-couplers to
protect the module against high voltage spikes, as well as ground potential differences. For easy
user access, TRP-C24 can enter configuration mode and self-test mode with outer dip-switch.
TRP-C24 support both ASCII and Modbus protocol, with a full set of command, dual watch-dog,
and auto reset function the module can be remote controlled by PC in ASCII or Modbus RTU
protocol.
1-1.Features
Wide input range DC power supply.
Support ASCII and Modbus RTU protocol.
Supports baud rates from 1.2Kbps to 115.2 Kbps.
Digital output signal with 3750Vrms isolation protection.
Dual watchdog: Module’s firmware, host computer traffic.
LED for each channels working status.
DIN-Rail and panel mount support.
Configured and self-test by external dip-switch.
Support screw terminal and external DC power adaptor.
TRP-C08U USB To 4 RS232 Isolated Converter
1. Introduction
The TRP-C08U allows you to simultaneously connect 4 RS-232
serial devices to system by using a
USB interface. Each one can be independent setting different
serial data format and baud-rate.
The user may also aim at the special BAUD-RATE demand to set up
by separately.
The RS232 interface offer TXD, RXD, GND signal connection type.
TRP-C08U is equipped with
3000V DC of isolation and +/-15KV ESD, as well as ground
potential differences. TRP-C08U
features a high-speed 256KB transmission rate, and supports
various O.S. The industry standard
DIN rail design enables users a fast and professional
installation.
-1. Features
USB-2.0 device controller.
Allow user custom adjust baud-rates.
Each Port can impendent set up the baud-rate and data
format.
On-Chip 512-Byte FIFO for upstream and downstream data
transfers for serial Port.
System gets four serial port when the converter plug in.
Direct power from USB port , no need external power supply.
3000 VDC isolation protection on RS232.
Power and TXA/RXA/TXB/RXB/TXC/RXC/TXD/RXD communication LED
indicator
Din-Rail (option)or panel mount Driver support:
Driver Support: Android/Win8.1/Vista64/32,Windows
98/ME/2000/XP/WIN 7/CE5.0~7.0, and
Linux, and Mac OS .
1-2. Specification
Input: USB 2.0 protocol.
RS232 output: TXD,RXD.GND.
Data Format: Asynchronous data with all common combination
of bits, parity, stop
Parity type: None, odd, even mark, space.
Data bit: 5, 6, 7, 8
Stop bits: 1, 1.5, 2.
Cable: USB 2.0 type A to type B cable.
Communication speed: form 300bps to 256Kbps.
RS-232 line protection: +/- 15KV ESD.
Connection type: Screw terminal for maximum AWG #12~30 wire.
DIN rail and panel mount support.
Power consumption: 70mA by USB power.
Operating environment: 0 to 65℃.
Storage temperature: -20 to 65℃.
Dimension: 151mm X 75mm X 26mm.
Weight: 395g.
Humidity: 10-90% non-condensing.
TRP-C08S
USB to -1xRS232+1x(422+485)
1. Introduction
The TRP-C08S allows you to connect 2 serial devices
simultaneously by using a USB interface.
With auto configuration in data format, baud rate and RS485
data flow direction control TRP-C08S
is able to automatically configure RS-232, RS-422 and RS-485
signals, data format and baud rate
without outer switch setting. TRP-C08S is equipped with 3000V
DC of isolation and internal surge
protection on each data line to protect the computer and
converter against high voltage spikes, as
well as ground potential differences. TRP-C08S also features a
high-speed 256 Kbps transmission
rate and supports various O.S. The industry DIN rail and panel
mounting design enable user a fast
and professional installation.
1-1. Features
USB-2.0 Device Controller
On-Chip 512-Byte FIFO for upstream and downstream data
transfers for serial Port
System gets two serial port when the converter plug in
Auto switching RS422/485 detecting
Auto direction flow control on RS485.
Auto baud rate switching from 300bps to 256 Kbps.
Direct power from USB port , no need external power supply
3000 VDC isolation protection on RS422/485.
Surge protection on RS422/485 data line.
Power and TXA/RXA/TXB/RXB communication LED indicator
Din-Rail (option)or panel mount Driver support:
Driver Support: Android/Win8.1/Vista64/32,Windows
98/ME/2000/XP/WIN 7/CE5.0~7.0, and
Linux, and Mac OS
TRP-C08M (7840)_Manual-4xRS232+(422+485)
1. Introduction
TRP-C08M is a USB to 4 ports RS232/422/485 Isolated Converter
support 3KV isolation, The
RS422/485 interface Surge Protection to ensure the stability of
the transmitted data, applications in
harsh industrial environments.
TRP-C08M bridge using the latest USB chip it has high anti-
interference ability, with heavy electric
system with a stable job.
TRP-C08M can set up a separate data format baud-rate and other
self-defined baud-rate.
TRP-C08M has the ability to automatically select RS232/422/485,
through a simple wiring,
automation management.
Two power input TRP-C08M support, optional USB power or
external input power supply, two
forward to provide power overload protection.
TRP-C08M simple to use, users first install the driver, you can
plug and play ready to use, very
convenient.
1-1. Features
USB-2.0 Device Controller.
Support 3KV isolation in RS232/RS422/485 interface.
Customer-specified Baud rates are also supported.
Each Port cans impendent set up the baud-rate and data
format.
On-Chip 512-Byte FIFO for upstream and downstream data
transfers for serial Port.
Fully PLC support such as Mitsubishi Q,FX and FATEK
serial....
Auto direction flow control on RS-485.
Auto baud rate switching from 75bps to 921.6 Kbps.
Auto switching RS232/422/485 interface.
256 byte buffer for upstream and downstream data flow.
Direct power from USB port or external power.
Surge protection on RS422/485 data lines.
Power and TX/RX communication LED indicator.
DIN rail or panel mount support.
Driver Support: Android/Win8.1/Vista64/32,Windows
98/ME/2000/XP/WIN 7/CE5.0~7.0, and
Linux, and Mac OS .
TRP-C08H
USB to 2 RS232 and 2 RS422/485 Isolated Converter
1. Introduction
The TRP-C08H allows you to connect 4 serial devices simultaneously by using a USB interface.
With auto configuration in data format, baud rate and RS485 data flow direction control TRP-C08H
is able to automatically configure RS-232, RS-422 and RS-485 signals, data format and baud rate
without outer switch setting. TRP-C08H is equipped with 3000V DC of isolation and internal surge
protection on each data line to protect the computer and converter against high voltage spikes, as
well as ground potential differences. TRP-C08H also features a high-speed 256 Kbps transmission
rate and supports various O.S. The industry DIN rail and panel mounting design enable user a fast
and professional installation.
1-1. Features
USB-2.0 device controller.
On-Chip 512-Byte FIFO for upstream and downstream data transfers for serial Port.
System gets four serial port when the converter plug in.
Auto switching RS422/485 detecting.
Auto direction flow control on RS485.
Auto baud rate switching from 300bps to 256 Kbps.
Direct power from USB port , no need external power supply.
3000 VDC isolation protection on RS422/485.
Surge protection on RS422/485 data line.
Power and TXA/RXA/TXB/RXB communication LED indicator
Din-Rail (option)or panel mount Driver support:
Driver Support: Android/Win8.1/Vista64/32,Windows 98/ME/2000/XP/WIN 7/CE5.0~7.0, and
Linux, and Mac OS .
1. Introduction
The TRP-C08 allows you to connect your serial devices to systems by using a USB
interface. With auto configuration in data format, baud rate and RS485 data flow direction control.
TRP-C08 is able to automatically configure RS232, RS422 or RS485 signals to baud rate without
external switch setting. TRP-C08 is equipped with 3000V DC of isolation and internal
surge-protection on each data lines to protect the host computer and converter against high
voltage spikes, as well as ground potential difference. TRP-C08 also features a high-speed 256
Kb/s transmission rate, and supports various O.S. The industry DIN rail and panel mounting
design enable user a fast and professional installation.
1.1. Features
Full compliance with the USB V1.0 and 2.0 specification.
System gets 1 COM port when the converter is connected.
Auto data format detecting.
Auto direction flow control on RS485.
Auto baud rate switching from 75 bps to 6M bps.
256 byte buffer for upstream and downstream data flow.
Direct power from USB port , no external power necessary.
3000V DC isolated protection.
Surge protection on RS422/485 data lines.
Power/TX/RX mode LED indicator.
DIN rail or panel mount support.
Driver support: WIN8/WIN7/WIN98/ME/2000/XP/CE3.0, and Linux, and Mac OS.
TRP-C07: RS422/485 isolated repeater.
1. Introduction
TRP-C07 is designed to extend the RS422 and RS485 signals to another 4000ft (1200m)
distance and increase the maximum number of connected nodes up to 32 sets. Aside from
extension function TRP-C07 provides with auto configuration features in data format detecting,
baud rate setting and RS485 data direction flow control. TRP-C07 is equipped with
photo-couplers and internal surge protection to protect the module and all data lines against high
voltage spikes, as well as ground potential differences. The industry standard DIN rail and panel
mounting design enable user a fast and professional installation. TRP-C07 is the ideal solution
for the user who wants to automate their application quickly, safely and cost-effectively.
1-1. Features
Wide input range DC power supply.
Automatic data format configuration.
Auto direction flow control on RS485.
Auto baud rate switching from 300bps to 115.2Kbps.
RS485 bi-directionally communication.
3000 DC isolated protection.
Surge protection on RS422/485 data lines.
Power/TX/RX mode LED indicator.
Support screw terminal and external DC adapter.
DIN rail or panel mount support.
1-2. Specification
Power input voltage: DC +10V to +30V.
Power input type: Support screw terminal or external DC adaptor.
Interface: Industrial plug-in screw terminal.
RS485 signal: differential 2 half-duplex wires. (D+,D-).
RS422 signal: differential 4 full-duplex wires. (TX+,RX+,TX-,RX-).
Plug-in screw terminal wiring: Accepts AWG - #12~30 wire.
Distance: extend RS422/485 signal up to 4000ft. (1200M).
Isolation voltage: 3000V DC.
LED indicator: Power, TX, and RX.
Power consumption: 1.2 watt.
Operating Temperature:-20 to 65℃.
Storage Temperature: -20 to 65℃
Humidity: 10-90% Non-condensing.
Dimension: 151mm X 75mm X 26mm
Weight: 380g.
2. TRP-C07 Hardware descript
1. Introduction
TRP-C07 is designed to extend the RS422 and RS485 signals to another 4000ft (1200m)
distance and increase the maximum number of connected nodes up to 32 sets. Aside from
extension function TRP-C07 provides with auto configuration features in data format detecting,
baud rate setting and RS485 data direction flow control. TRP-C07 is equipped with
photo-couplers and internal surge protection to protect the module and all data lines against high
voltage spikes, as well as ground potential differences. The industry standard DIN rail and panel
mounting design enable user a fast and professional installation. TRP-C07 is the ideal solution
for the user who wants to automate their application quickly, safely and cost-effectively.
1-1. Features
Wide input range DC power supply.
Automatic data format configuration.
Auto direction flow control on RS485.
Auto baud rate switching from 300bps to 115.2Kbps.
RS485 bi-directionally communication.
3000 DC isolated protection.
Surge protection on RS422/485 data lines.
Power/TX/RX mode LED indicator.
Support screw terminal and external DC adapter.
DIN rail or panel mount support.
1-2. Specification
Power input voltage: DC +10V to +30V.
Power input type: Support screw terminal or external DC adaptor.
Interface: Industrial plug-in screw terminal.
RS485 signal: differential 2 half-duplex wires. (D+,D-).
RS422 signal: differential 4 full-duplex wires. (TX+,RX+,TX-,RX-).
Plug-in screw terminal wiring: Accepts AWG - #12~30 wire.
Distance: extend RS422/485 signal up to 4000ft. (1200M).
Isolation voltage: 3000V DC.
LED indicator: Power, TX, and RX.
Power consumption: 1.2 watt.
Operating Temperature:-20 to 65℃.
Storage Temperature: -20 to 65℃
Humidity: 10-90% Non-condensing.
Dimension: 151mm X 75mm X 26mm
Weight: 380g.
2. TRP-C07 Hardware descript
1. Introduction
The TRP-C06H allows 2 RS232 line signal to be bi-directionally converted to RS422 or RS485
standard and transmit data up to 1.2KM. Featuring automatic data format and baud rate detect
function users just need to plug the unit and go without extra configuration efforts. TRP-C06H is
equipped with 3000V DC of isolation and internal surge protection to protect the host computer
and converter against high voltage spikes, as well as ground potential differences. The industry
standard DIN rail and panel mounting design enable user a fast and professional installation.
1-1. Features
Wide range input DC power supply.
Automatic data format configuration.
Auto direction flow control on RS485.
Auto baud rate switching from 300bps to 115.2Kbps.
3000V DC isolated protection.
Surge protection on RS422/485 data lines.
Power/TX/RX mode LED indicator
Support screw terminal and external DC adaptor.
DIN rail or panel mounts support.
1-2. Specifications
Power input voltage: DC +10V to +30V.
Host connection: 2 standard D-Sub 9 pin female connectors.
RS232 signal: TXD, RXD, GND.
RS232 interface: Standard D-Sub 9 pin female connector.
RS422/485 interface: Industrial plug-in screw terminal.
RS485 signal: differential 2 half-duplex wires (D+, D-).
RS422 signal: differential 4 full-duplex wires. (TX+, RX+, TX-, RX-)
Communication speed: form 300bps to 115.2Kbps auto detecting.
RS422/485 line protection: Against surge, short circuit, voltage peak.
Distance: up to 4000ft (1200M).
Isolation voltage: 3000V DC.
Plug-in screw terminal wiring: Accepts AWG #12 ~ 30 wires.
Signal LED: Power on, TXA, RXA, TXB, RXB.
Power supply: Screw terminal, or external DC adapter.
Power consumption: 1.3W
Operating environment: -20 to 65℃.
Storage temperature: -20 to 65℃.
Humidity: 10-90% Non-condensing.
Dimension: 151mm X 75mm X 26mm.
Weight: 375g.
1. Introduction
The TRP-C06 allows RS232 line signal to be bi-directionally converted to RS422 or RS485
standard and transmit data up to 1.2KM. Featuring automatic data format and baud rate detect
function user just need to plug in the unit and go without extra configuration efforts. TRP-C06 is
equipped with 3000V DC of isolation and internal surge protection on data lines to protect the
host computer and converter against high voltage spikes, as well as ground potential differences.
The industry standard DIN rail and panel mounting design enable user a fast and professional
installation.
1-1. Features
Wide input range DC power supply.
Automatic data format configuration.
Auto direction flow control on RS485.
Auto baud rate switching from 300bps to 115.2Kbps.
3000 VDC isolated protection.
Surge protection on RS422/485 data lines.
Power/TX/RX mode LED indicator.
Support screw terminal and external DC power adaptor.
Din rail or panel mounts support.
Contact the business
Website
Opening Hours
Monday | 09:00 - 17:00 |
Tuesday | 09:00 - 17:00 |
Wednesday | 09:00 - 17:00 |
Thursday | 09:00 - 17:00 |
Friday | 09:00 - 17:00 |