Ideas for a masonry hotel sitting on a warm humid climate. currently on the drawing board increasing from 34 to 45 rooms using the same amount of sq meters and keeping the principles of shade and mix mode ventilation that gave birth to the idea.
Urbanización Canto Del Vallés
Casa Numero 27 en Unidad Cerrada, en lote mirando al sol de la Mañana
El área total del lote por escrituras = 80,6 mts 2
El área construida de la casa según licencia de construcción =
132.3 mts 2 interiores
11.0 mts 2 de patio exterior
Total= 143.3 mts 2
Excelentes Acabados, Maderas de Calidad. Roble, Abarco y Pisos en Porcelanato y Vinilo importado, Salpicadero en Vidrio, Diseño de iluminación incluido, se entrega con lámparas, CERO PLAFONES. Todas las Puertas y closets tienen 2.40 metros de Alto, Bisagras en Acero Inoxidable.
Primer Piso:
-Garaje Con Área para Camioneta, Ingreso por Puerta en Roble Macizo, Sala, Comedor y Cocina con Zona de Ropas. Área de Patio Exterior Contigua al Comedor, Baño social completo y Cuarto Útil Bajo La Escalera.
Segundo Piso:
-Escalera en Roble Con llegada al Hall de Habitaciones. 3 habitaciones, Habitación principal con Vestier y Baño. Habitación auxiliar Número 1 con Balcón y closet. Habitación auxiliar Número 2 con Baño y Closet.
Administración 283K / mes
Predial 167 K / trimestre
Raiz
Nos complace presentar el diseño para un hotel Ubicado en un clima cálido húmedo y apenas sobre el nivel Del Mar. El diseño de este hotel se constituye con base en las siguientes estrategias. En primer lugar, está diseñado para funcionar bajo el concepto de “modo mixto “donde el confort térmico depende tanto de la ventilación natural como la mecánica, en este edificio las habitaciones cuentan con soluciones individuales de sistemas tipo Mini Split mientras que las áreas comunes son ventiladas naturalmente con ventilación cruzada. La segunda estrategia de tipo pasiva es un riguroso diseño de sombras que a través de la fachada principal del edificio bloquea el acceso directo del sol a las habitaciones proporcionando confort térmico y eficiencia en el consumo de los equipos de Aire Acondicionado. Finalmente, a causa de los periodos secos en la región donde se localiza el edificio el diseño contempla 2 tanques de 5000 lts. Para el abastecimiento de aparatos sanitarios mediante recolección de las aguas lluvias.
We’re glad to present the design of a fine hotel located in a warm humid climate barely above the sea level. In first place a “mixed mode” design is devised to provide mechanically air-conditioned rooms through individual mini split systems addressing the thermal comfort in each one of the rooms. In the other hand the common areas are naturally ventilated through crossed ventilation through the envelope and partition walls. Secondly the front façade of the building is conceived to block the direct sun into the rooms throughout the year providing guests with comfortable shadows and the property owners with a mechanical equipment operating under higher cost efficiency. Finally due the long dry periods in the region, the building is equipped with two 5000 lts. rain water collection tanks for hydraulic fixtures internal supply.
A monthly solar radiation analysis based on weather hourly data, is the approach used to understand which is the smartest way of using the envelope to capture the heat gains. 3 different options are tested in these maps
A monthly solar radiation analysis based on weather hourly data, is the approach used to understand which is the smartest way of using the envelope to capture the heat gains.
Located 10 min Near the international airport of Medellín and around 2150mt above sea level, this site has been commissioned the design of a 150 sq mt hillside house.
Our first step is to understand the climate of our site, for this purpose using hourly data collected in 2018 at the international airport we can produce a Psychrometric chart that allows us to see the behavior of the temperature and humidity throughout the year and how often do this conditions fall within the polygon of the comfort zone.
The second diagram plots a comfortable or not vote defined by the Colors pink, meaning yes or white meaning no. In other words, each of the pink rectangles mean that for that specific hour of the 2018 the climate conditions averaged between 35 and 55 % of relative humidity and the air temperature felt between 23 and 26 C degrees. Comfort standards as per the AHRAE adaptive comfort model for this latitude.
Out of 8760 hours accounted for the year only during 1050 hours or 12 % of the time these conditions were recorded, with uncomfortable hours happening mostly at night. After A thorough climate study, we will provide a mass plan to set the house with the best orientation on the hill and improve the comfort performance in the night through smart data driven design.
Daylight, air permeability, landscape and shade define the design in the rear part of this building
Iluminación natural , permeabilidad al aire , verde y sombra definen el diseño en la parte de atrás en este edificio